I received the next error in the EventLog:
Error # 1
Segment Id: EVN_EventType
Sequence Number: 1
Field Number: 2
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: Trailing delimiter found
Alternate Encoding System: HL7-BTAError # 2
Segment Id: EVN_EventType
Sequence Number: 1
Field Number: 4
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: Trailing delimiter found
Alternate Encoding System: HL7-BTAetc
This can be easily solved by turning the property TrailingDelimiterAllowed to True (in the send pipeline component BTAHL7 2.X Assembler):
Note: if you have defined a party, then you can also configure this in the BTAHL7 Configuration Explorer: